The Multi-Function Calibrator is useful for the calibration of Digital Multimeters, Clamp Meters, Digital Panel Meters, Analog Panel Meters, LCR Meters & Non-Contact Type Tachometers. It is a variable source with different ranges of DC Voltage, AC Voltage, DC Current, AC Current, Frequency, Resistance, Capacitance, Inductance & RPM (Non-Contact Type). It has been designed to calibrate the maximum ranges of a variety of models of multimeters available in the market. The calibrator gives very stable Output. Stability is suitable enough to calibrate 41/2 and 41/2 DMM and Clamp-on Meters. By using this source along with a high-resolution standard Multimeters user can calibrate even 51/2 DMM. Calibrator has a micro controller unit, which handles all the parameter selection and range selection logic. Micro controller drives to the set of relays as per the logic program. Relays rout the outputs.
Model | ZMMFC 5.5.3 | |
Input Power Supply | 230V AC ± 5% @ 50Hz. | |
Input Protection | Calibrator is Protected by I/P OV (Over Voltage) & I/P UV (Under Voltage) | |
DC Voltage Ranges | 200mV, 2V, 20V, 200V, 1000V | |
AC Voltage (45Hz to 1000Hz) Ranges | 200mV, 2V, 20V, 200V, 1000V | |
DC Current Ranges | 2mA, 20mA, 200mA, 2000mA, 20A | |
AC Current (45Hz to 1000Hz) Ranges | 2mA, 20mA, 200mA, 2000mA, 20A | |
Frequency Range | 45Hz to 1000Hz | |
Fixed Resistance | 1Ω, 10Ω, 100Ω, 1kΩ, 10kΩ, 100kΩ, 1MΩ, 10Ω, 100MΩ | |
Fixed Inductance | 10µH, 100µH, 1mH, 10mH, 100mH | |
Fixed Capacitance | 1nF, 10nF, 100nF, 1µF, 10µF | |
RPM Range (Non-Contact Type) | 2700 to 60000 RPM | |
Accuracy @ 20oC to 28oC, RH <75% | AC Voltage: ± 0.15 % of reading ± 15 digit | DC Voltage: ± 0.1 % of reading ± 5 digit |
AC Current: ± 0.15 % of reading ± 15 digit | DC Current: ± 0.1 % of reading ± 5 digit | |
Frequency: ± 0.1 Hz | Resistance: ± 0.2 % | |
Inductance: ± 2% | Capacitance: ± 2 % | |
RPM (Non Contact Type): ± 0.1 % of Reading ± 5 Digit | ||
Operating Temperature | 15oC to 50oC | |
Power OFF Storage Temperature | 10oC to 70oC | |
Required Earth to Neutral | Less than 1 V AC | |
Drift due to ageing | 50 PPM per year. | |
Short term stability of the set value | 350 PPM | |
Display | 51/2 Digit 7 segment red LED display for Voltage & Current | |
4 Digit 7 segment red LED display for Frequency | ||
Selection of AC/DC Parameters | By up and down keys and bar of LED to indicate selected parameter | |
Selection of Ranges | By up and down keys and bar of LED to indicate selected range | |
Setting of Voltage & Current | By decade switch | |
Setting of Frequency | By multi turn potentiometer | |
Frequency Range Selection | By Toggle Switch for Normal Mode: 45 to 1 kHz & Filter Mode: 50 to 60 Hz provided at front side. | |
Resistor mode & Inductance / Capacitance mode Selection | By Toggle switch | |
R/L/C Range Selection | By Rotary switch | |
Dimension & Weight | 600mm(W) X 600mm(D) X 170mm(H) | 33kg. (Approx.) |