

The Multi Function Calibrator is useful for the calibration of Digital Multimeters, Clamp Meters, Digital Panel Meters, and Analog Panel Meters. It is a variable source with different ranges of DC Voltage, AC Voltage, DC Current, and AC Current. It has been designed to cover the calibration of maximum ranges of a variety of models of Multi meters available in the market. The calibrator gives output, which is very stable. Stability is suitable enough to calibrate 41/2 and 43/4 DMM and Clampon Meters. By using this source along with a high-resolution standard Multimeters user can calibrate even 51/2 DMM. Calibrator has a micro controller unit, which handles all the parameter selection and range selection logic. Micro controller drives to the set of relays as per the logic program. Relays rout the outputs.
Model | ZMMFC 5.5.1 | |||
Input Power Supply | 230V AC @ 50Hz. | |||
Input Protection | Calibrator is Protected by I/P OV (Over Voltage) & I/P UV (Under Voltage) | |||
DC Voltage Ranges | 200mV, 2V, 20V, 200V, 1000V | |||
AC Voltage (45Hz to 1000Hz) Ranges | 200mV, 2V, 20V, 200V, 1000V | |||
DC Current Ranges | 2mA, 20mA, 200mA, 2000mA, 20A | |||
AC Current (45Hz to 1000Hz) Ranges | 2mA, 20mA, 200mA, 2000mA, 20A | |||
Frequency Range | 45Hz to 1000Hz | |||
Accuracy @ 20oC to 28oC, RH <75% | AC Voltage: 0.15% ±15 Digit | DC Voltage: 0.1% ±5 Digit | Frequency: ±0.1 Hz | |
AC Current: 0.2% ±15 Digit | DC Current: 0.2% ±5 Digit | |||
Operating Temperature | 10oC to 40oC | |||
Power OFF Storage Temperature | 5oC to 70oC | |||
Required Earth to Neutral | Less than 1 V AC | |||
Drift due to ageing | 50 PPM per year. | |||
Short term stability of the set value | 350 PPM | |||
Display | 5½ Digit 7 segment red LED display for Voltage & Current | |||
4 Digit 7 segment red LED display for Frequency | ||||
Selection of AC/DC Parameters | By up and down keys and bar of LED to indicate selected parameter | |||
Selection of Ranges | By up and down keys and bar of LED to indicate selected range | |||
Setting of Voltage & Current | By decade switch | |||
Setting of Frequency | By multi turn potentiometer | |||
Dimension & Weight | 550mm(W) X 600mm(D) X 170mm(H) | 32kg. (Approx.) |
Note : Accuracies specified at 25 deg C, RH <75%, basic accuracy ±10 digits for DC parameters & basic accuracy ±15 digits for AC parameters.